제품 사양 및 구성


Platform model Jet direction Suggested applications Tools Gas type Major functions
plabo-v
PLABO-V
vertical
Vertical
maryland-bridge
Maryland bridge
T2n T3n T4n
T2n, T3n, T4n
bio-gas
Puredenti Bio Gas
Cementation
List Detail Note
Platform model PLABO-V
Jet direction Vertical
Suggested application Maryland bridge
Tool model T2n, T3n, T4n
Major functions Cementation
Power consumption 220 volts AC (single phase), less than 100 Watts Use a power cord with ground wire connected at all times
Maximum continuous operating time Within 30 minutes Repeated processing of multiple samples
Normal processing time More than 30 seconds Automatic processing of multiple slots
Ambient operating temperature of electronic device Below 40 degrees Celsius
Bio Gas model Puredenti Bio Gas Inquiry to the seller
Bio Gas cartridge volume Below 1 L Inquiry to the seller
Size 226 x 455 x 375
Weight Less than 20 kg
guide1

Maryland bridge mounting

guide2

Select project

guide3

Select slot and check energy before start

guide4

Check processing time and progress

guide5

Process done

Inspection list Detail Sample inspection Full inspection
Device motion durability test

Operate the device at room temperature for over 120 hours (Sample inspection)

Operate the device at room temperature for over 24 hours (Sample/Full inspection)

O O
Plasma device operation test Operate the plasma jet at room temperature for over 30 minutes O
Cartridge load test Damage test with potential load of up to 350 kg during shipping O
Cartridge fire test Gas cartridge damage test under several hundred degrees Celsius during shipping and handling O
Device motion heat resistance test Operate the device for over 24 hours in an environment above 40 degrees Celsius O
Device motion cold resistance test Operate the device for over 10 hours in an environment below 10 degrees Celsius O
Temperature sensor operation test Heat insulation function operation test of the device O
KC certification Electromagnetic wave and power noise test certification O
Ozone certification

Ozone emission measurement by accredited testing institute (Sample inspection)

Ozone emission measurement according to accredited testing methods (5 cm, 30 m³, etc.) (Sample/Full inspection)

O O
Drop test Drop test for device from a height of approximately 1 meter O
Blood absorption test Blood surface absorption test after plasma treatment (Fixture) O
Contact angle test Surface contact angle test after plasma jet treatment O
Zirconia-Titanium SBS test Bond strength test according to ISO 16506 standard O
Porcelain SBS test Bond strength test according to ISO 29022 standard O
XRD measurement XRD using titanium samples (Analysis test carbon, etc.) O

Safety Guidelines

This device is an electronic device that uses high voltage. Forcing the front door open to operate the device may result in electrical damage and is dangerous. Always use the provided touch program functionality only.

The power cord for this device must include a type 1 grounded power supply and grounding wire.

Using any gas other than the genuine Puredenti gas cartridge will shorten the device's lifespan and its performance cannot be guaranteed.

This device is developed for surface treatment and bioactivation of dental materials. Do not use it for any purposes other than the specified and approved uses.

Prolonged use in environments above 40 degrees Celsius can cause serious damage to the equipment. Whenever possible, use the device in a cool or well-ventilated area.

When using the device, harmful gases such as ozone may be generated when reacting with air. Use the device in a well-ventilated area or under an exhaust hood. Periodically replace the harmful gas filter located at the back of the equipment.

Only refill and use genuine Puredenti gas cartridges from the manufacturer or an authorized source. In the event that a bio-gas cartridge is exposed to fire, high temperatures, or high pressure environments, familiarize yourself with emergency procedures such as evacuation. Move to an area with fresh air if exposed excessively.

Keep the station components, which are part of the assembly of genuine Pure Dentigas, clean and ensure they are free from contamination. Contaminants can unpredictably alter the characteristics of the gas mixture.

If you experience any abnormalities while using this device, consult a doctor or seek medical attention immediately. Regularly inspect for signs of damage, corrosion, or any other issues with the gas cartridge and device. If any problems are detected, contact your supplier immediately and do not use the device or cartridge.

Employees handling this device must receive proper training on its safe handling, maintenance, and usage. Training sessions can reinforce safety protocols and reduce potential risks.

Warranty and A/S

We provide free repair services for damages caused solely by defects in the device itself, not due to user negligence (carelessness and incompetence). The period for free repair service is up to 1 year from the date of delivery of the device.

Even within the warranty period, any malfunctions resulting from forced or unauthorized operations beyond the procedures outlined in this manual, or from disassembly of the device, may incur repair charges or may not be repaired according to the policy of the seller.

If there are consumer demands during the A/S occurrence and repair period of this device, temporary rental of a device through the seller is possible.

In the event of A/S occurrence, the principle is to utilize regular delivery services based on mutual agreement between the customer and the seller. If regular delivery service is not feasible, alternative transportation methods (such as two-wheeled vehicles) may be utilized to provide service support.

The manufacturer reserves the right to make arbitrary functional modifications and performance upgrades for the purpose of enhancing customer service, including programs for this device. Users must be informed in advance if they do not wish to accept these modifications.

For any other issues arising from the use of this device, please contact the seller or reach out to the service center for assistance and resolution.